Product Details:
| Minimum Order Quantity | 45 Kilogram |
| Usage/Application | Air Conditioner |
| Cylinder Weight | 45 kg |
| Brand | Floron |
| Packaging Type | Cylinder |
| Type | Hfcs |
| Specific Name | R407C |
| Refrigerant Grade | R407C |
| Packaging Size | 45 |
| Moisture | 10 ppm W/W Maximum |
| Pentafluoroethane | 25+/-2% (HFC-125) W/W |
| Particulates | Visually Clean to Pass Solids |
| High Boiling Residue | 0.01% V/V, Maximum |
| Volatile Impurities | 0.5% W/W Maximum |
| Difluoromethane | 23+/-2% (HFC-32), W/W |
NOTE : " We Deals In Bulk Quantity " .
R-407C is a blend refrigerant developed as a substitute for HCFC-22. It is a mixture of HFC-32, HFC-125, and HFC-134a, and is a zeotropic refrigerant. It requires liquid filling to prevent change in composition. Its level of pressure is approximately the same as that of HCFC-22. It is highly compatible with ester oil and ether oil (It is not compatible with mineral oils like naphthenic oil etc. which is normally used with HCFC-22). Its moisture solubility is approximately the same level as that of HCFC-22.
Product Details:
| Minimum Order Quantity | 58 Kilogram |
| Cylinder Weight | 45 kg |
| Pack Size | 58 Kg |
| Brand | MPCL |
| Packaging Type | Cylinder |
| Specific Name | R407C |
| Packaging Size | 9.5 Kg and 58 Kg |
| Types | Hfcs |
| Boiling Point | -43.6 Deg C |
| Usage/Application | Refrigerant |
| Recommended Lubricant | POE |
| GWP | 1774 |
| Composition | R-134a (52%) R-125 (25%) R-32 (23%) |
NOTE : " We Deals In Bulk Quantity " .
R-407C is a blend refrigerant developed as a substitute for HCFC-22. It is a mixture of HFC-32, HFC-125, and HFC-134a, and is a zeotropic refrigerant. It requires liquid filling to prevent change in composition. Its level of pressure is approximately the same as that of HCFC-22. It is highly compatible with ester oil and ether oil (It is not compatible with mineral oils like naphthenic oil etc. which is normally used with HCFC-22). Its moisture solubility is approximately the same level as that of HCFC-22.
Main Applications:
Residential and commercial air conditioning systems. Heat pumps Non-flooded evaporator chillers. Other unitary air conditioning systems.
Lubrication:
POE lubricants must be used with Fluoro 4o7C since its components are not miscible with the mineral oil or alkylbenzene Lubricants.
Charging:
Due to the zeotropic nature of fluoro 407C, it should be charged as a Liquid to prevent fractionation (changes in refrigerant composition). In situations where vapor is normally charged into a system, a valve should be installed in the charging line to flash the liquid to vapor while charging.
Product Details:
| Minimum Order Quantity | 45 Kilogram |
| Specific Name | R407C |
| Usage/Application | Air Conditioning |
| Packaging Type | Cylinder |
| Boiling Point | -43.6 Deg C |
| Types | Hcfcs |
| Packaging Size | 8 and 45 Kg |
| Brand | Freon |
| Nominal Composition | HFC-32/125/134A |
Freon 407C (R-407C) is a R-22 replacement primarily for air-conditioning. It's a HFC blend that requires a POE lubricant. R-407C is included in the U.S. EPA SNAP de-listing of HFCs that will no longer be acceptable in new equipment in certain end use applications in the U.S. market.
Ashrae:
Replaces:
Applications:
Benefits:
Phaseout Schedule:
Lubricant Recommendation